2week bifocal Disposable Contact Lenses

J&J / acuvue oasys multifocal

acuvue oasys multifocal

Features

1. Maintains moisture on the lens surface throughout the day.
2. Center-near design
3. UV-protection (UV-A 96% UV-B 99%)
4. It has a variety of optical design that helps get comfortable vision.

CENTER THICKNESS 0.07mm (-3.00D)
WATER CONTENT 38%
BC 8.4mm
D 14.3mm
FDA GROUP I
SPECIFICATION VALUE -9.00~-0.25,
±0.00~+5.00 (0.25step)
ADD Low (+0.75 ~ +1.25)
Mid (+1.50 ~ +1.75)
High (+2.00 ~ +2.50)
B&L / AQUALOX multifocal

AQUALOX multifocal

Features

1. High oxygen permeability
2. Retains moisture for 16 hours.
3. Center-near design
4. Its unique 3-zone progressive optical design offers clear vision.

CENTER THICKNESS 0.07mm (-3.00D)
WATER CONTENT 46%
BC 8.5mm
D 14.2mm
FDA GROUP I
SPECIFICATION VALUE +6.00D ~ +4.50D (0.50step)
+4.00D ~ -7.00D (0.25step)
-7.50D ~ -10.00D (0.50step)
ADD Low (~+1.50D)
High (~+2.50D)
Menicon / 2week menicon premio multifocal toric

2week menicon premio multifocal toric

Features

1. The first Multifocal+Toric lens in Japan.
2. It offers stable and clear vision.
3. Center-near design

CENTER THICKNESS 0.08mm(-3.00D)
WATER CONTENT 40%
BC 8.6mm
D 14.2mm
FDA GROUP I
SPECIFICATION VALUE 0.00 ~ -6.00 (0.25step)
-6.50 ~ -10.00 (0.50step)
Cylinder -0.75, -1.25
AX 180° / 90°
ADD +1.00
Alcon / Air OPTIX plus HydraGlyde multifocal

Air OPTIX plus HydraGlyde multifocal

Features

1. Seamless vision at all distances, near through far.
2. Resistant to protein or lipid deposits.
3. Retains moisture on the lens surface throughout the day.
4. Center-near design

CENTER THICKNESS 0.08mm(-3.00D)
WATER CONTENT 33%
BC 8.6mm
D 14.2mm
FDA GROUP I
SPECIFICATION VALUE +5.00 ~ -10.00 (0.25step)
ADD Low / Med / High
B&L / Medalist Fresh Fit Comfort Moist multifocal

Medalist Fresh Fit Comfort Moist multifocal

Features

1. Seamless vision at all distances, near through far.
2. ComfortMoist® Technology helps keep comfort all day.
3. Adequate oxygen permeability.
4. Center-near design

CENTER THICKNESS 0.07mm(-3.00D)
WATER CONTENT 36%
BC 8.6mm
D 14.0mm
FDA GROUP III
SPECIFICATION VALUE +5.00 ~ +4.50 (0.50step)
+4.00 ~ -7.00 (0.25step)
-7.50 ~ -10.00 (0.50step)
ADD LOW( ~ +1.50) / HIGH( ~ +2.50)
SEED / 2weekpure multistage

2weekpure multistage

Features

1. UV-protection. Marking on the lens.
2. Made in Japan.
3. Center-far design

CENTER THICKNESS 0.09mm
WATER CONTENT 58%
BC 8.6mm
D 14.2mm
FDA GROUP IV
SPECIFICATION VALUE +5.00 ~ +0.50 (0.25step)
±0.00
-0.50 ~ -6.00 (0.25step)
-6.50 ~ -10.00 (0.50step)
ADD +0.75 / +1.50
coopervision / Biofinity multifocal

Biofinity multifocal

Features

1. Balanced Progressive® Technology Design offers clear vision.
2. Seamless vision at all distances, near through far.
3. Center-far design

CENTER THICKNESS 0.10mm (-3.00D)
WATER CONTENT 48%
BC 8.6mm
D 14.0mm
FDA GROUP I
SPECIFICATION VALUE +6.00 ~ -6.00 (0.25step)
-6.50 ~ -10.00 (0.50step)
ADD +1.00D / +1.50D / +2.00D / +2.50D
B&L / Medalist multifocal

Medalist multifocal

Features

1. Resistant to protein or lipid deposits and dryness.
2. Seamless vision at all distances, near through far.
3. Center-near design

CENTER THICKNESS 0.08mm (-3.00D)
WATER CONTENT 38.6%
BC 9.0/8.7mm
D 14.5mm
FDA GROUP I
SPECIFICATION VALUE +5.00 ~ +4.50(0.50step)
+4.00 ~ -7.00(0.25step)
ADD Low( ~ +1.50) / High( ~ +2.50)
Menicon / 2week menicon premio multifocal

2week menicon premio multifocal

Features

1. 2 lens design available.
PRG: Power to look near, intermediate, far is placed in a balanced fashion.
BIF: Power to look nearby objects is placed by the side of nose.
2. Adequate oxygen permeability.
3. Center-near design

CENTER THICKNESS 0.08mm(-3.00D)
WATER CONTENT 40%
BC 8.6mm
D 14.2mm
FDA GROUP I
SPECIFICATION VALUE +5.00 ~ -6.00 (0.25step)
-6.50 ~ -13.00 (0.50step)
ADD +1.00 / +2.00

Office hours

Weekday

11:30-13:45/15:00-19:30

Saturday

11:00-13:45/15:00-19:00

Sunday,Holiday

11:00-18:00
(no lunchtime.)

Closed

Our clinic is closed on 12/31, 1/1, 1/2, 1/3.

Location

9th floor of Hulic Shinjuku Building,3-25-1, Shinjuku, Shinjuku-ku, Tokyo, 160-0022

TEL:03-5363-0507

Map

Questionnaire

SNS

TEL・FAX

Online appointment

Links

Doctor career

Director:Yasuhiro Shinkawa

(Registered Recipient of a Diploma of Ophthalmology)

Memberships

Japan Ophthalmological Society
Japanese Retina and Vitreous Society
Japanese Society of Ophthalmic Surgeons

Certification of Completion

Course of Ophthalmic PDT Study Group
Number of cataract surgery up to the present:About 4000

Career

2001 Graduate-Medical Department of Kumamoto University
2002 Department of Ophthalmology Kyoto University School of medicine
2002 Shimada Municipal Hospital
2008 Japanese Red Cross Society
2010 Kitano Hospital The Tazuke Kofukai Medical Research Institute
2014 Shinjuku-Higashiguchi Eye Clinic


 

Doctor:Fumiyo Hasegawa

(Registered Recipient of a Diploma of Ophthalmology)

Memberships

Japan Ophthalmological Society
Japan Ophthalmologists Associasion
Japanese Association for Strabismus and Amblyopia(JASA)

Career

1992 Graduate- Medical Department of Teikyo Univercity
2002 The head ophthalmologist at International Catholic Hospital
2020 Shinjuku-Higashiguchi Eye Clinic

Main Thesis

Sequelae of ocular trauma in schools.(Japanese)
A case of periodic upper and lower strabismus with loss of periodicity after cataract surgery(Japanese)
Quantitative analysis of eye movement during a cover test for patients with intermittent exotropia(Japanese)



 
We have 7 full-time service orthoptist, 2 part-time orthoptists, 1 full-time nurse and 4 part-time nurses in our clinic.
Another several ophthalmologists are working here.